TW9

Thermocouple Welding Unit

THERMCOUPLE WELDING UNIT TW9

 

OPERATATION

To weld a wire to a steel body, the magnet is used to make a return contact

The thermocouple wire is stripped back and the pliers are used to grip this wire about 25mm from the cut end

The ‘charge' button is pushed and released.  After a short time the LEDS change from ‘charging to ‘ready’

The thermocouple wire is held firmly against the steel surface and the ‘weld’ button is pushed.  This welds the wire to the steel body

TW9 FEATURES

High efficiency converter between battery re-charge

Mains LED shows when the battery is on charge

Low Battery LED shows when the battery needs re-charging

Tool Storage is built into the case

Very low battery inhibits operation

Supplied with tools and mains charging lead

 

TECHNICAL DETAILS

Discharge energy                      40 watt-seconds maximum,

                                                    18 watt-second minimum

Battery re-charge time              6 to 8 hours

Supply voltage                          100-130 VAC or          200-260              VAC

Dimensions                                225mm(H) 214mm(W) 95mm(D)

Globe logo